Offered for sale a used refractive index detector, Shodex RI-71. It originates from a running laboratory and is believed to be in a good state. Yet, instrument is a new arrival and the preformance still needs to tested/confirmed in our own laboratory.  The RI-71 Refractive Index Detector is an excellent, general purpose HPLC detector for GPC molecular weight determination and for detecting compounds having no UV adsorption.

Features include:

  • High performance: Low noise level and higher stability with small dead volume all combine to enhance the Shodex RI-71 detection limit.
  • Automatic compensation: A decrease in sensitivity caused by stains on the flow cell are compensated by an automatic increase in the brightness of the lamp.
  • Easy operation: Incorporation of a microprocessor enables high resolution auto zero function.
    Activation of the PURGE ON/OFF button enables easy replacement of the eluent in the reference cell.
  • Automatic operation: Several types of input/output terminals enable automatic operation.

Specifications include:

  • Sensitivity range: 7 x10-6
  • Noise: 2.5 x10-9 RIU/hour
  • Drift: 2.5 x10-9 RIU/hour
  • Standard analytical flow cell volume: 8 ul
  • Weight: 27 lbs.
  • Measurements: 10.5 W x 15.25 F-B x 6.25H inches
  • Electrical: 100, 120, 220, 240v 50, 60Hz
  • Temperature setting: 35deg-C(with 76deg-C thermal fuse)

A new Shodex RI detector will cost approximately € 9000

Out of stock


Are you interested in this product or require more info ?

Just let us know and we’ll get in touch as soon as possible.

    Your name (required)

    Your Email (required)

    Subject

    Your message


    Description

    Offered for sale a used refractive index detector, Shodex RI-71. It originates from a running laboratory and is believed to be in a good state. Yet, instrument is a new arrival and the preformance still needs to tested/confirmed in our own laboratory.  The RI-71 Refractive Index Detector is an excellent, general purpose HPLC detector for GPC molecular weight determination and for detecting compounds having no UV adsorption.

    Features include:

    • High performance: Low noise level and higher stability with small dead volume all combine to enhance the Shodex RI-71 detection limit.
    • Automatic compensation: A decrease in sensitivity caused by stains on the flow cell are compensated by an automatic increase in the brightness of the lamp.
    • Easy operation: Incorporation of a microprocessor enables high resolution auto zero function.
      Activation of the PURGE ON/OFF button enables easy replacement of the eluent in the reference cell.
    • Automatic operation: Several types of input/output terminals enable automatic operation.

    Specifications include:

    • Sensitivity range: 7 x10-6
    • Noise: 2.5 x10-9 RIU/hour
    • Drift: 2.5 x10-9 RIU/hour
    • Standard analytical flow cell volume: 8 ul
    • Weight: 27 lbs.
    • Measurements: 10.5 W x 15.25 F-B x 6.25H inches
    • Electrical: 100, 120, 220, 240v 50, 60Hz
    • Temperature setting: 35deg-C(with 76deg-C thermal fuse)

    A new Shodex RI detector will cost approximately € 9000

    Do you have a question?

    Drop us a line by compiling the form below. We will be more than happy to reply to any of your questions!