Sold out

Used Parker Balston Nitrogen generator, model 76-94

1,250.00 ex.

The offered Ultra high purity Nitrogen generator w/hydrocarbon removal, Parker Balston Model 76-94 Nitrogen Generator is engineered to transform standard compressed air into 99.99% or 99.9999% nitrogen, exceeding the specification of UHP cylinder gas. It produces up to 1.1 LPM of UHP nitrogen gas and is engineered and packaged in a small cabinet which fits on or under any benchtop. The system eliminates the need for costly, inconvenient high pressure nitrogen cylinders. The system is ideal for carrier gas and make-up gas applications of for instance GC instruments. It might also be used for evaporation applications.

Specifications:
– Nitrogen Purity: 99.9999%
– Min inlet pressure: 60 psi
– Max inlet pressure: 125 psi
– 60 PSI: 500 cc/min
– 125 PSI: 1100 cc/min
– Recommended inlet temperature: 78°F (25°C)
– Max ambient operating temperature: 100°F (38°C)
– Max air consumption: 42 LPM
– Inlet connection: 1/4″ NPT (female)
– Outlet connection: 1/8″ compression

The instrument was tested in our laboratory and is in a good condition.

Out of stock


Are you interested in this product or require more info ?

Just let us know and we’ll get in touch as soon as possible.

    Your name (required)

    Your Email (required)

    Subject

    Your message


    Description

    The offered Ultra high purity Nitrogen generator w/hydrocarbon removal, Parker Balston Model 76-94 Nitrogen Generator is engineered to transform standard compressed air into 99.99% or 99.9999% nitrogen, exceeding the specification of UHP cylinder gas. It produces up to 1.1 LPM of UHP nitrogen gas and is engineered and packaged in a small cabinet which fits on or under any benchtop. The system eliminates the need for costly, inconvenient high pressure nitrogen cylinders. The system is ideal for carrier gas and make-up gas applications of for instance GC instruments. It might also be used for evaporation applications.

    Specifications:
    – Nitrogen Purity: 99.9999%
    – Min inlet pressure: 60 psi
    – Max inlet pressure: 125 psi
    – 60 PSI: 500 cc/min
    – 125 PSI: 1100 cc/min
    – Recommended inlet temperature: 78°F (25°C)
    – Max ambient operating temperature: 100°F (38°C)
    – Max air consumption: 42 LPM
    – Inlet connection: 1/4″ NPT (female)
    – Outlet connection: 1/8″ compression

    The instrument was tested in our laboratory and is in a good condition.

    Folder Nitrogen Generator Parker Balston 76-94

    Do you have a question?

    Drop us a line by compiling the form below. We will be more than happy to reply to any of your questions!

    [your_form_shortcode_here]