1377 – Used CleanAir Microbiological safety cabinet EF/S4

3,700.00 ex.

This used CleanAir Microbiological safety cabinet EF/S4 was manufactured in 2011. It was in operation in a microbiological laboratory in the Netherlands until it closed a few months ago. The CleanAir was always serviced by a specialized organization and is therefore in a good condition.

The offered used CleanAir Microbiological safety cabinet EF/S4 Class II ensures the highest level of protection for operator, product and environment. It also minimizes hazards inherent to working with agents assigned to biosafety levels 1, 2 and 3. They are suitable for microbiological research with, for example, bacteria, viruses and allergens. The users are protected by inflow, the products by HEPA-filtered laminar downflow in the working area (30% exhaust, 70% recirculation). HEPA-filtered exhaust air ensures environmental protection. The design meets the highest requirements in terms of safety, ergonomics, ease of use and reliability.

Specifications:

  • With sloped window (8 mm laminated glass, 2 layers)
  • Sound level: < 55 dB A
  • Average downflow speed (in work mode): 0,36 ± 0,05 m/s
  • Average downflow speed (in standby mode): 0,10 – 0,20 m/s
  • Minimal average inflow speed in top of front aperture (in work mode): > 0,28 m/s
  • Average inflow speed in whole front aperture (in work mode): > 0,5 m/s
  • Exhaust air flow (work mode): 400 ± 25 m3/h
  • Electrical requirements: 230 V ± 5%, 50 Hz
  • External dimensions (WxDxH): 1373 x 794 x 1602 mm (H excluding stand of 800 mm)
  • Internal dimensions (WxDxH): 1180 x 550/470 x 744 mm
  • Weight: 215 kg

For more specifications and information about this CleanAir safety cabinet, please refer to the Clean Air EF Manual.

1 in stock


Are you interested in this product or require more info ?

Just let us know and we’ll get in touch as soon as possible.

    Your name (required)

    Your Email (required)

    Subject

    Your message


    Description

    This used CleanAir Microbiological safety cabinet EF/S4 was manufactured in 2011. It was in operation in a microbiological laboratory in the Netherlands until it closed a few months ago. The CleanAir was always serviced by a specialized organization and is therefore in a good condition.

    The offered used CleanAir Microbiological safety cabinet EF/S4 Class II ensures the highest level of protection for operator, product and environment. It also minimizes hazards inherent to working with agents assigned to biosafety levels 1, 2 and 3. They are suitable for microbiological research with, for example, bacteria, viruses and allergens. The users are protected by inflow, the products by HEPA-filtered laminar downflow in the working area (30% exhaust, 70% recirculation). HEPA-filtered exhaust air ensures environmental protection. The design meets the highest requirements in terms of safety, ergonomics, ease of use and reliability.

    Specifications:

    • With sloped window (8 mm laminated glass, 2 layers)
    • Sound level: < 55 dB A
    • Average downflow speed (in work mode): 0,36 ± 0,05 m/s
    • Average downflow speed (in standby mode): 0,10 – 0,20 m/s
    • Minimal average inflow speed in top of front aperture (in work mode): > 0,28 m/s
    • Average inflow speed in whole front aperture (in work mode): > 0,5 m/s
    • Exhaust air flow (work mode): 400 ± 25 m3/h
    • Electrical requirements: 230 V ± 5%, 50 Hz
    • External dimensions (WxDxH): 1373 x 794 x 1602 mm (H excluding stand of 800 mm)
    • Internal dimensions (WxDxH): 1180 x 550/470 x 744 mm
    • Weight: 215 kg

    For more specifications and information about this CleanAir safety cabinet, please refer to the Clean Air EF Manual.