1377 – Used CleanAir Microbiological safety cabinet EF/S4

3,700.00 ex.

This used CleanAir Microbiological safety cabinet EF/S4 was manufactured in 2011. It was in operation in a microbiological laboratory in the Netherlands until it closed a few months ago. The CleanAir was always serviced by a specialized organization and is therefore in a good condition.

The offered used CleanAir Microbiological safety cabinet EF/S4 Class II ensures the highest level of protection for operator, product and environment. It also minimizes hazards inherent to working with agents assigned to biosafety levels 1, 2 and 3. They are suitable for microbiological research with, for example, bacteria, viruses and allergens. The users are protected by inflow, the products by HEPA-filtered laminar downflow in the working area (30% exhaust, 70% recirculation). HEPA-filtered exhaust air ensures environmental protection. The design meets the highest requirements in terms of safety, ergonomics, ease of use and reliability.

Specifications:

  • With sloped window (8 mm laminated glass, 2 layers)
  • Sound level: < 55 dB A
  • Average downflow speed (in work mode): 0,36 ± 0,05 m/s
  • Average downflow speed (in standby mode): 0,10 – 0,20 m/s
  • Minimal average inflow speed in top of front aperture (in work mode): > 0,28 m/s
  • Average inflow speed in whole front aperture (in work mode): > 0,5 m/s
  • Exhaust air flow (work mode): 400 ± 25 m3/h
  • Electrical requirements: 230 V ± 5%, 50 Hz
  • External dimensions (WxDxH): 1373 x 794 x 1602 mm (H excluding stand of 800 mm)
  • Internal dimensions (WxDxH): 1180 x 550/470 x 744 mm
  • Weight: 215 kg

For more specifications and information about this CleanAir safety cabinet, please refer to the Clean Air EF Manual.

Out of stock


Are you interested in this product or require more info ?

Just let us know and we’ll get in touch as soon as possible.

    Your name (required)

    Your Email (required)

    Subject

    Your message


    Description

    This used CleanAir Microbiological safety cabinet EF/S4 was manufactured in 2011. It was in operation in a microbiological laboratory in the Netherlands until it closed a few months ago. The CleanAir was always serviced by a specialized organization and is therefore in a good condition.

    The offered used CleanAir Microbiological safety cabinet EF/S4 Class II ensures the highest level of protection for operator, product and environment. It also minimizes hazards inherent to working with agents assigned to biosafety levels 1, 2 and 3. They are suitable for microbiological research with, for example, bacteria, viruses and allergens. The users are protected by inflow, the products by HEPA-filtered laminar downflow in the working area (30% exhaust, 70% recirculation). HEPA-filtered exhaust air ensures environmental protection. The design meets the highest requirements in terms of safety, ergonomics, ease of use and reliability.

    Specifications:

    • With sloped window (8 mm laminated glass, 2 layers)
    • Sound level: < 55 dB A
    • Average downflow speed (in work mode): 0,36 ± 0,05 m/s
    • Average downflow speed (in standby mode): 0,10 – 0,20 m/s
    • Minimal average inflow speed in top of front aperture (in work mode): > 0,28 m/s
    • Average inflow speed in whole front aperture (in work mode): > 0,5 m/s
    • Exhaust air flow (work mode): 400 ± 25 m3/h
    • Electrical requirements: 230 V ± 5%, 50 Hz
    • External dimensions (WxDxH): 1373 x 794 x 1602 mm (H excluding stand of 800 mm)
    • Internal dimensions (WxDxH): 1180 x 550/470 x 744 mm
    • Weight: 215 kg

    For more specifications and information about this CleanAir safety cabinet, please refer to the Clean Air EF Manual.